75C high water temp Commerical Hot Water & Shower Water Heat Pump
- KOLANT commercial hot water heat pump provide High efficiency and energy saving.
- All year round operation, continuous hot water and shower water.
- High flexibility, suitable for most hot water systems.
- Maximum water temperature up to 75℃ (hightemperature series).
- All important parts from world famous brands, reliable and durable.
- CB/CE standard conformity, designed according to international standards.
Your best choice for commercial hot water heat pump
Energy consumption of hot water accounts for a considerable percentage in commercial buildings. According to some investigation, this percentage can even be as high as 40% in some hotels, nursing homes, hospitals etc. Heat pumps, however, generate hot water mostly with renewable energy are especially suitable for commercial hot water project. Using KOLANT heat pumps as the heating devices or replacing those existed boilers in commercial buildings makes great benefits in
economic and environmental prospects. With large capacity range from 10kW to
250kW, KOLANT commercial heat pumps provides various choices for users to get the most cost-effective solution for hot water projects.
Multi-protection function built inside
- Multi-protection function built inside Kolant hot water heat pump such as leakage protection, high/low voltage protection, high temperature protection, current overload protection start delay, water flow protection, heat exchanger anti-freezing protection and so on, to fully protect the normal operation and service life of the hot water heat pump.Water-water heat exchange has no hidden dangers such as electric leakage, fluorine leakage and corrosion, dry burning of electric water heaters, and no toxic and harmful gases such as CO, so water use is safer.
Wider Operating Range
KOLANT hot heat pump can reliably and efficiently run with a bigger operating range. EVI model can working with good efficiency at -30℃ ambient temperature. Normal heat pumps even can not work lower than -15 ℃ ambient temperature.
Kolant 75°C High - Temperature Heat Pump applications
With Kolant EVI technology, inverter technology, special refrigerant R134a,R515 usage and Kolant expert calibration, Kolant heat pump provide max 75°C High outlet water temp even in cold weather.
The 75°C high – temperature heat pump is a remarkable technological innovation with wide – ranging applications and distinct advantages.
In industrial settings, it is used for various heating processes. For example, in the food industry, it can be applied to sterilize food products at the required high temperatures. In textile manufacturing, it provides heat for dyeing and drying processes, ensuring high – quality production.
One of its primary advantages is energy efficiency. By using heat from the environment, it consumes far less electricity compared to traditional heating methods, which not only reduces operational costs but also helps in environmental protection by lowering carbon emissions. Additionally, its high – temperature output makes it suitable for replacing fossil – fuel – based boilers in some cases, further promoting sustainable development. This heat pump offers a reliable and eco – friendly heating solution for multiple sectors.
Smart WIFI control
By downloading our APP in your mobile phone, it is possible for you to conveniently control a DC inverter heat pump from KOLANT at any time, anywhere. Just imagine that you turn on your heat pump and set it to a comfortable temperature before you leave office, then you will enjoy the pleasant environment as soon as you get home, It is fantastic, isn’t it?
Modbus Protocol built inside
Beside Kolant heat pump wired controller and central controller, KOLANT commercial
heat pumps are specially designed to be compatible with modbus protocol, this means your heat pumps can be controlled by a building
automatic control system if it is necessary. You can control and monitor your heat pump working status through computer or any other modbus controller.
High Energy Saving
KOLANT commercial heat pumps are especially suitable for hot
water projects. Obtaining up to 75% free heat from ambient air,
KOLANT commercial heat pumps make great sense to reduce your
energy bill by replacing traditional heating devices such as electric
boiler, oil boiler or gas boiler.
Full model for flexiable model selection
KOLANT provides various models for selection ranging from 10kW to 250kW. Users can select the most suitable model according to their hot water demand or existed tank volume to get the most cost-effective solution.
High quality components, long lifetime
All the key components are from leading suppliers to make sure the quality and lifetime. For example, the DC inverter compressors are from Panasonic, the high efficiency plate heat exchangers are from Swep etc.
Technical Data
KRS-140E/SN3-M1(ZK) | KRS-160E/SN3-M1(ZK) | KRS-210E/SN3-M1(ZK) | KRS-260E/SN3-M1(ZK) | KRS-310E/SN3-M1(ZK) | KRS-390E/SN3-M1(ZK) | KRS-460E/SN3-M1(ZK) | KRS-540E/SN3-V(ZK) | KRS-800E/SN3-V(ZK) | ||
Heating Capacity | kW | 13.5 | 16 | 20.5 | 26 | 31 | 39 | 46 | 54 | 80 |
Power Supply | V/Ph/Hz | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 |
Input Power | kW | 3.7 | 4.5 | 5.8 | 7.5 | 9 | 11.2 | 13.5 | 15.4 | 23.5 |
Running Current | A | 6.37 | 7.75 | 9.99 | 12.91 | 15.5 | 19.28 | 23.24 | 26.52 | 40.46 |
Max. Input Power | kW | 5.55 | 6.75 | 8.7 | 11.25 | 13.5 | 16.8 | 20.25 | 23.1 | 35.25 |
Max. Running Current | A | 9.56 | 11.62 | 14.98 | 19.37 | 23.24 | 28.93 | 34.87 | 39.77 | 60.69 |
Refrigerant | R134a | R134a | R134a | R134a | R134a | R134a | R134a | R134a | R134a | |
Compressor | Copeland | Copeland | Copeland | Copeland | Copeland | Copeland | Copeland | Copeland | Copeland | |
Compressor Type | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | |
Compressor Quantity | 1 | 1 | 1 | 2 | 2 | 3 | 3 | 3 | 3 | |
Outlet Water Temp | ºC | 70 | 70 | 70 | 65 | 65 | 65 | 65 | 65 | 65 |
Max. Outlet Water Temp | ºC | 85 | 85 | 85 | 85 | 85 | 85 | 80 | 80 | 85 |
Water Flow | m3/h | 2.9 | 3.4 | 4.4 | 5.6 | 6.7 | 8.4 | 9.9 | 11.6 | 17.2 |
Condenser | Tube in shell | Tube in shell | Tube in shell | Tube in shell | Tube in shell | Tube in shell | Tube in shell | Tube in shell | Tube in shell | |
Water Pressure Drop | Kpa | 55 | 55 | 60 | 55 | 55 | 55 | 55 | 60 | 60 |
Water Connection Tube | mm | DN25 | DN25 | DN25 | Dn40 | Dn40 | Dn50 | Dn50 | Dn50 | Dn50 |
Noise | dB(A) | <57 | <57 | <58 | <60 | <61 | <63 | <63 | <70 | <71 |
Electric Protection | I | I | I | I | I | I | I | I | I | |
Mechanical Protection | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | |
Net/Gross Weight | kg | 119/137 | 139/157 | 150/168 | 249/294 | 268/316 | 398/460 | 428/490 | 530/620 | 620/710 |
Dimension | mm | 752x690x965 | 752x690x965 | 752x690x965 | 1450x702x1060 | 1450x702x1260 | 2150x765x1290 | 2150x765x1290 | 2000x980x1840 | 2000x980x2012 |
Packing Dimension | mm | 840x750x1100 | 840x750x1100 | 840x750x1100 | 1525x805x1220 | 1525x805x1420 | 2250x865x1450 | 2250x865x1450 | 2130x1100x2050 | 2130x1100x2200 |