HP18kwoutlook1
9KW Heatpump NewDesign2
1823KWHeatpumpKolant
airwaterheatpump
9-14KWHeatpumps
HP18kwoutlook1
9KW Heatpump NewDesign2
1823KWHeatpumpKolant
airwaterheatpump
9-14KWHeatpumps

Inverter Heating Cooling Heat Pump

  • KOLANT DC inverter heat pump is an overall energy solution for your home.
  • Heating Cooling + Domestic Hot Water in one solution.
  • Compatible with Solar thermal, Solar PV
  • Enery Class A++ with R410a
  • Enery Class A+++ with R32 and R290 refrigerant
  • European standard inverter heat pump
  • With Wifi control function

KOLANT DC inverter heat pump is intended to provide an overall energy solution for your home. it heats or cools your home and at the same time produce domestic hot water to meet all your needs though one device.

  • Solar ready: Compatible with solar thermal panels to be the second heat source of the system.
  • Hot water: Domestic hot water is available all year round.
  • Heating: Suitable for floor heating, radiator heating or fan coil heating.
  • Cooling(optional): Cooling function is available when it is necessary and suitable for fan coil  cooling or area cooling.

DC inverter technology

Standard heat pumps are either ON or OFF. No matter how much the current heat demand is, these heat pumps run at full load even if only for a short time. As any motorist knows, frequently stopping and starting is not a particularly efficient way to drive, as it sends consumption levels through the roof.

In contrast, KOLANT DC inverter heat pump employs not only a DC inverter compressor but an intelligent control system, which operates much more evenly and efficiently. With inverter technology, the heat pump matches its output to the prevailing heat demand with a high degree of precision. Instead of a stop-start pattern, a much more even and energy efficient operation results, which closely mirrors the actual heat demand of the building.

Precise Heat Demand Match

The heating capacity of KOLANT DC inverter heat pump can be precisely regulated from 20% to 100% according to the actual heat demand. Accordingly, the water temperature in the system will be steadily controlled with a very small deviation of no more than 0.5℃ so as to create a comfortable living environment.

Inverter Heating Cooling Heat Pump3

Wider Operating Range

KOLANT DC inverter heat pump can reliably and efficiently run with a bigger operating range. For example, even when the environment temperature as cold as -20℃ , the heat pump still can provide warm water with high water temperature and high heating output. However, normalheat pumps even can not work in this situation.

Kolant Heat Pump Benefits to you
Inverter Heating Cooling Heat Pump35

Energy efficiency class A++ (tested by TUV)

KOLANT DC inverter heating technology makes a very high energy efficiency within all the permitted operating range. For example, when the ambient air is not so cold and the heat demand is not so big, the heat pump runs with low heat output but a particularly high efficiency. However, when ambient air is extremely cold, the heat pump runs with full load to reduce or eliminate the aid of the booster heater. The intelligent control system is always trying to maximize the efficiency of the whole heating system. As a matter of fact, all KOLANT DC inverter heat pumps have energy efficiency class A++.

EN14825 certificates with Energy efficiency class A++ by TUV

RJ-90HN2-BPD RJ-120HN2-BPD RJ-160HN2-BPD
Models RJ-90H/N2-BPD RJ-120H/N2-BPD RJ-160H/N2-BPD
Declared heating capacity Pdh kW 8.756 12.316 15.177
Annual heating demand Qh kWh/year 18,090 25,445 31,356
Annual electricity consumption Qhe kWh/year 4,567 5,987 7,878
SCOP (seasonal coefficient of performance) 4.14 4.25 3.98
Energy efficiency class A++ A++ A++

* Tested under average climate conditions applied for floor heating according to EN14825

Your annual energy bill by different heating devices

 

DC Inverter Heat pump Normal ON/OFF Heat pump Gas Diesel Electricity
Calorific value 860kcal/kWh 860kcal/kWh 860kcal/kWh 10,200kcal/L 860kcal/kWh
Energy efficiency 425%(A++) 300%(A) 85% 85% 95%
Energy price 0.167€/kWh 0.167€/kWh 0.071€/kWh 1.61€/L 0.167€/kWh
Annual heating demand Qh 25,445kWh 25,445kWh 25,445kWh 25,445kWh 25,445kWh
Annual energy consumption 5,987kWh 8,482kWh 29,935kWh 2,524L 26,784kWh
Annual energy bill 999.8€ 1,416.5€ 2,125.4€ 4,063.6€ 4,488.0€
Kolant Heat Pump Advantage for you
Inverter Heating Cooling Heat Pump7

Smart WIFI control

By downloading our APP in your mobile phone, it is possible for you to conveniently control a DC inverter heat pump from KOLANT at any time, anywhere. Just imagine that you turn on your heat pump and set it to a comfortable temperature before you leave office, then you will enjoy the pleasant environment as soon as you get home, It is fantastic, isn’t it?

Inverter Heating Cooling Heat Pump8

Intelligent LCD controller

The smart touch screen controller is friendly to all users, users can easily operate it without big effort. It is also very convenient for service people to check all the sensor data and the running state, set parameters with the aid of the controller.

High quality components, long lifetime

All the key components are from leading suppliers to make sure the quality and lifetime. For example, the DC inverter compressors are from Panasonic, the high efficiency plate heat exchangers are from Swep etc.

Technical Data

RJ-90HN2-BPD RJ-120HN2-BPD RJ-160HN2-BPD RJ-200HN2-BPD
Model RJ-90H/N2-BP RJ-120H/N2-BP RJ-160H/N2-BP RJ-200H/N2-BPD
Performance data according to EN14511
Heating output/power input/COP at A7/W35 kW/kW/- 8.7/1.90/4.58 12.0/2.70/4.44 15.6/3.60/4.33 19.5/4.61/4.23
Heating output/power input/COP at A2/W35 kW/kW/- 8.8/2.18/4.04 11.5/2.90/3.97 15.5/3.99/3.88 19.6/5.12/3.83
Heating output/power input/COP at A-7/W35 kW/kW/- 7.1/2.39/2.97 9.3/3.08/3.02 12.8/4.52/2.83 16.3/5.78/2.82
Heating output/power input/COP at A7/W45 kW/kW/- 8.5/2.40/3.54 11.4/3.12/3.65 14.7/4.28/3.43 18.8/5.52/3.41
Heating output/power input/COP at A-7/W45 kW/kW/- 6.8/2.87/2.37 9.0/3.74/2.41 12.3/5.46/2.25 14.7/6.46/2.28
Heating output/power input/COP at A7/W55 kW/kW/- 8.0/2.64/3.03 10.8/3.53/3.06 14.1/4.66/3.03 17.6/5.99/2.94
Cooling output/power input/EER at A35/W7 kW/kW/- 7.1/2.50/2.84 9.6/3.30/2.91 12.0/4.50/2.67 15.1/5.89/2.56
Energy efficiency class according to EN14825
Average climate for floor heating A++ A++ A++ A++
Average climate for radiator heating A++ A++ A++ A++
Electrical data
Power supply 230V/50Hz 230V/50Hz 230V/51Hz 230V/52Hz
Maximum power consumption kW 3.7 4.8 6 6.8
Maximum input current A 16.2 21 26.2 29.8
Application range
Water temperature range Heating 18~60 18~61 18~62 18~63
Cooling 8~28 8~29 8~30 8~31
Ambient air temperature range Heating -20~43 -20~44 -20~45 -20~46
Cooling 15~43 15~44 15~45 15~46
Other technical data
Type of refrigerant R410A R411A R412A R413A
Maximum operating pressure MPa 4.2 5.2 6.2 7.2
Type of evaporator Fine-tube Fine-tube Fine-tube Fine-tube
Rated water flow rate m³/h R410A R411A R412A R413A
Internal water pressure loss KPa 19 20 22 24
Diameter of water connection mm DN25 DN25 DN32 DN33
Noise level at 1 meter dB(A) 54 56 57 58
Net dimensions (W*D*H) mm 1115*450*926 115*450*1076 1115*450*1276 1115*450*1480
Packing dimensions (W*D*H) mm 1170*490*1055 1170*490*1205 1170*490*1420 1170*490*1620
Net/gross weight kg 100/115 120/138 130/150 150/170

Installation Cases

Get Free Quote of Inverter Heating Cooling Heat Pump

Related News

With the breakthrough of heat pump low-temperature technology and the support of policies, the Northeast heat pump market is becoming […]

Heat pumps are avoiding more gas and carbon dioxide emissions in Europe than ever, new calculations from the European Heat […]

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)
If you have any questions, please do not hesitate to contatct with us.
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.