Solar PV direct drive Heat Pump
- KOLANT DC Inverter Solar PV direct drive Heat Pump is an overall energy solution for your home Heating, Cooling + Domestic Hot Water in one solution.
- Direct solar Photovoltaic Electricity power supply connection
- Compatible with Solar thermal, Solar PV
- Enery Class A+++ with R32 refrigerant gas
- European standard inverter heat pump
- With Wifi control function
- With modbus protocol and RS485 interface
Cross-industry Integrated New Energy Heat Pump
Kolant Innovative green energy methods such as solar power generation, wind energy, photovoltaic power storage, etc. are deployed and used with heat pump energy consumption to achieve seamless switching between dual power inputs, give priority to the use of photovoltaic energy, and eliminate the need for secondary conversion, which greatly reduces user energy
Sunny Day Mode. “Free” heating/cooling.
When there is abundant sunlight and the photovoltaic system generates electricity that fully meets all the power consumption requirements of the unit, free heating/cooling can be achieved.
Cloudy Day Mode. Power grid intelligent supplementation.
When the sunlight is insufficient, the photovoltaic system supplies partial power, and the power grid supplements it intelligently to ensure the stable operation of the unit.
Night Mode. Power supply from the power grid.
During the night period, the photovoltaic system does not generate electricity, and the power grid supplies electricity directly. The energy consumption is equivalent to that of the unit itself.
More Energy Source For More Comfortable Home
Replacing traditional coal boilers, oil burner, electric boilers, and ordinary air conditioners,
brings you more energy-efficient and greener options.
Low Air Temp Strong Heating
It is designed to capture solar energy even in low – temperature environments. By leveraging advanced heat – transfer technologies and high – efficiency collectors, it can convert solar energy into powerful heating output. This ensures that homes and commercial spaces remain warm and cozy, regardless of the cold outside.
0 cost when Solar PV direct driving
Adopt Multi noise reducing technology
0.1°C temp tolerance Super comfort
Auto switch solar and Grid electricity
Full DC Inverter + EVI
– 35°C Heating
DC inverter + EVI technology to operate strongly and heat (up to 60°C) stably in ambient -35°C.
Reliable & Safe
Leading COP increasing technology, strict production control and international brand components result stable product quality
Remote Control
Mobile APP control and Modbus control are both available for remote control monitor and maintenance.
Technical Data
Models | Air temp/outlet water temp | GFRB-85H/N8 -BBPEEVI | COP | GFRB-110H/N8 -BBPEEVI | COP | GFRB-150H/N8 -BBPEEVI | COP | GFRB-185H/N8 -BBPEEVI | COP | GFRB-240H/N8 -BBPEEVI | COP |
Heating capacity/Power input (KW) | at A20/W35°C | 10.6/1.89 | 5.61 | 14.42/2.88 | 5.01 | 21.1/3.89 | 5.42 | 22.8/4.4 | 5.18 | 29.5/6.01 | 4.91 |
at A7/W35°C | 8.59/1.87 | 4.59 | 10.6/2.55 | 4.16 | 14.7/3.31 | 4.44 | 18.8/4.4 | 4.27 | 23.1/5.34 | 4.33 | |
at A7/W45°C | 7.91/2.23 | 3.55 | 9.97/3.14 | 3.18 | 13.5/4.1 | 3.29 | 17.8/5.24 | 3.4 | 22.6/6.11 | 3.7 | |
at A2/W35°C | 7.65/1.81 | 4.23 | 9.54/2.49 | 3.83 | 13.08/3.21 | 4.07 | 16.92/4.31 | 3.93 | 20.29/5.38 | 3.77 | |
at A2/W45°C | 7.04/2.15 | 3.27 | 8.97/3.06 | 2.93 | 12.02/3.97 | 3.03 | 16/5.12 | 3.13 | 18.7/6.4 | 2.92 | |
at A-12/W41°C | 5.9/2.45 | 2.41 | 6.3/2.7 | 2.33 | 10.2/4.35 | 2.34 | 11.6/5.04 | 2.3 | 14.7/5.88 | 2.5 | |
at A-20/W41°C | 5.4/2.56 | 2.11 | 5.61/2.72 | 2.06 | 8.9/4.23 | 2.1 | 10.5/4.97 | 2.11 | 13.7/5.78 | 2.37 | |
Cooling Capacity/Power input(KW) | at A35/ W18ºC | 9.2/2.7 | 3.41 | 11/3.3 | 3.33 | 13.9/4.2 | 3.31 | 15.6/4.8 | 3.25 | 20.1/6.2 | 3.24 |
at A35/W7ºC | 7.2/2.73 | 2.64 | 8.6/3.4 | 2.53 | 9.8/3.77 | 2.6 | 10.5/4.2 | 2.5 | 13.5/5.09 | 2.65 | |
Max.current (A) | 18 | 19 | 28 | 14.3 | 18.1 | ||||||
Max power input | 4KW | 5KW | 6KW | 7KW | 9KW | ||||||
Solar working max voltage | 340VDC | ||||||||||
Electric supply | 230V/50~60HZ | 400V/50~60HZ | 400V/50~60HZ | ||||||||
Max.Outlet water temperature | 60oC | ||||||||||
Working temperature range (oC) | -30 ~ 43 | ||||||||||
Refrigerant circuit | Refrigerant | R32 | |||||||||
DC Inverter compressor | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | ||||||
Heat exchange | Copper and Hydrauphilic Aluminum Fin | ||||||||||
Air flow (m3/h) | 2400 | 5800 | 6000 | 7000 | |||||||
Water circuit | Heat exchanger | High efficiency tube in shell heat exchanger | |||||||||
Inlet/Outlet pipe size | DN25(G1″) | DN25(G1″) | DN25(G1″) | DN25(G1″) | DN25(G1″) | ||||||
Water flow (m3/h) | ≥1.5 | ≥1.8 | ≥2.5 | ≥3 | ≥3.9 | ||||||
permitted pressure | ≤0.8MPa | ||||||||||
Unit dimensions WxHxD (mm) | 960*820*380 | 960*820*380 | 960*1270*380 | 960*1270*380 | 1030*1340*390 | ||||||
Pacage dimensions WxHxD (mm) | 1040*940*502 | 1040*940*502 | 1040*1390*502 | 1040*1390*502 | 1115*1510*510 | ||||||
Net weight (Kg) | 68 | 68 | 108 | 108 | 128 | ||||||
Gross weight (Kg) | 85 | 85 | 125 | 125 | 145 | ||||||
Noise level (dB(A)) | 56 | 56 | 59 | 59 | 60 | ||||||
Loading quantity for 20’/40′ container | 44/88 | 44/88 | 22/44 | 22/44 | 22/44 |